① 闃叉按鏉跨敤澶勪互鍙婇槻姘存澘鏉垮帤銆佽勬ā
1:闃叉按鏉挎澘鍘氬強綆浠
闃叉按鏉挎槸涓縐嶅熀浜庤仛鍚堢墿鏉愭枡鐨勯槻娓楅忔潗鏂欙紝鍙浠ラ槻姝㈡恫鎬佽仛鍚堢墿娉勬紡錛岄槻姝㈡皵浣撴尌鍙戙傚畠騫挎硾鐢ㄤ簬寤虹瓚錛屼氦閫氾紝闅ч亾鍜屽伐紼嬪緩璁俱
闃叉按鏉誇篃縐頒負鍦熷伐鑶溿閫氬父浣跨敤闃叉按鏉挎澘鍘氫負0.8mm鎴栨洿澶х殑鍦熷伐鑶滀綔涓洪槻姘存澘,闃叉按鏉挎澘鍘氬皬浜0.8mm鐨勫彨鍦熷伐鑶溿傚洜姝ら槻姘存澘鍘氬害鏄澶т簬0.08mm鐨勩傝繖鏄涓縐嶅熀浜庤仛鍚堢墿鏉愭枡鐨勯槻娓楅忔潗鏂欍備篃鏄鍧囪川鐨勯槻姘存澘鍜屽嶅悎闃叉按鏉褲
2:闃叉按鏉跨殑涓昏佸姛鑳
闃叉按鏉跨殑涓昏佹槸涓轟簡闃叉㈡皵浣撴尌鍙戝拰娑蹭綋娉勬紡銆傚洜涓洪槻姘存澘鏉垮帤鐨勮凍澶,鎵浠ュ湪宀╃煶宸ョ▼涓闃叉按鏉誇笉浠呮槸闃叉㈡笚閫忓拰闅旂伙紝榪樿兘鍔犲己鍜屼繚鎶ゃ
3:闃叉按鏉垮帤搴︿互鍙婅勬ā
闃叉按鏉挎槸涓縐嶅熀浜庤仛鍚堢墿鏉愭枡鐨勯槻娓楅忔潗鏂欙紝鍙浠ラ槻姝㈡恫鎬佽仛鍚堢墿娉勬紡錛岄槻姝㈡皵浣撴尌鍙戙
闃叉按鏉垮藉害涓鑸涓4~6m錛岄噸閲忎竴鑸涓200~1500g/騫蟲柟綾熾闃叉按鏉誇篃縐頒負鍦熷伐鑶溿閫氬父浣跨敤闃叉按鏉挎澘鍘氫負0.8mm鎴栨洿澶х殑鍦熷伐鑶滀綔涓洪槻姘存澘銆傛槸涓縐嶅熀浜庤仛鍚堢墿鏉愭枡鐨勯槻娓楅忔潗鏂欍
4:闃叉按鏉挎柦宸ュ伐鑹
1:鍩哄眰澶勭悊錛氶摵璁鵑潰娓呮磥錛屽湴鍩哄鉤鏁達紝鍧氱‖鍦燂紝瑁傜紳絳変笉鑳藉仛錛屼笉鑳芥湁閿嬪埄鐨勪笢瑗匡紝鐭沖ご錛屾湪媯嶇瓑銆傝崏鍧鑽夊睘浜庡柗闆鵑勯槻鑼冨洿錛屽繀欏誨幓闄ゆ牴閮ㄣ瀵逛簬鏉傝崏錛屽柗媧掗櫎鑽夊墏銆
2:鍦ㄨ啘鎺ヨЕ琛ㄩ潰涓婏紝閾鴻懼皬綺掑緞鐨勭爞鎴栫矘鍦熷眰浣滀負淇濇姢灞傦紝淇濇姢灞傜殑鍘氬害蹇呴』涓30cm鎴栨洿澶с
3:閾鴻炬柟娉:娌跨潃鏌愪釜鏂瑰悜閾鴻,涓嶈佸己鐑堟媺鎵,涓轟簡閫傚簲鏈哄熀搴х殑鍙樺艦,闇瑕佹湁涓瀹氱殑鍙鎵╁睍鎬с
浠ヤ笂灝辨槸闃叉按鏉挎澘鍘氫互鍙婅勬ā鐨勪粙緇,榪樻湁闃叉按鏉跨殑閾鴻炬柟娉曚簡,闃叉按鏉挎澘鍘氳揪鍒頒竴瀹氱▼搴︽墠鑳藉彨鍋氶槻姘存澘,鍚﹀垯鍙鑳藉彨鍋氬湡宸ヨ啘浜嗐
鍦熷反鍏斿湪綰垮厤璐逛負澶у舵彁渚涒滃悇瀹惰呬慨鎶ヤ環銆1-4瀹舵湰鍦拌呬慨鍏鍙搞3濂楄呬慨璁捐℃柟妗堚濓紝榪樻湁瑁呬慨閬垮潙鏀葷暐錛佺偣鍑繪ら摼鎺ワ細銆https://www.to8to.com/yezhu/zxbj-cszy.php?to8to_from=seo__m_jiare&wb銆戱紝灝辮兘鍏嶈垂棰嗗彇鍝~
② 誰知道隧道塑料防水板防水層鋪設應符合哪些規定
1.塑料防水板防水層由塑料防水板與緩沖層組成,並應採用分離式,首先進行緩沖層鋪設,再鋪設塑料防水板,塑料防水板厚度不小於1.5㎜;
2.塑料防水板應鋪設於隧道拱部及邊牆范圍,並與襯砌後排水系統形成防排水層;對於環境要求較高、排水限制嚴格的隧道地段,塑料防水板防水層宜採用全封閉鋪設;
3.隧道防水板應在初期支護變形基本穩定並經驗收合格後進行鋪設,鋪設時基層宜平整、無尖銳物,基層平整度應符合D/L≤1/6的要求;(D為初期支護基層相鄰兩凸面凹進去的深度;L為基層相鄰兩凸面間的距離。)
4.塑料防水板防水層應牢固地固定在基層上,固定點的間距應根據基層平整情況確定,拱部宜為0.5m~0.8m、邊牆宜為0.8m~1.0m、隧底宜為1.0m~1.5m。局部凹凸較大時,應在凹處加密固定點。
③ 璇烽棶闅ч亾闃叉按鏉挎柦宸ュ瓨鍦ㄧ殑甯歌佽川閲忛棶棰樺強澶勭悊鏂規硶
2.0mm鍘氱殑ECB錛岀﹀悎璁捐¤佹眰銆1錛屽父瑙侀棶棰樻槸甯傚満涓婃販涔變環鏍間笉涓銆備竴瀹氳侀夋嫨絎﹀悎鏍囧噯鐨勬潗鏂欍
2銆佹柦宸ヤ腑涓鐐硅佹敞鎰忕粏閮ㄨ妭鐐歸槻姘淬傚勭悊濂芥槑銆佹殫鎸栦氦鎺ュ勭殑闃叉按錛屽叾涓搴旈伩鍏嶅湪鏆楁寲孌典笌鏄庢寲孌典氦鎺ワ紝姝や綅緗鎺ョ紳澶勭悊鍥伴毦錛屽規槗鍑虹幇鏂藉伐璐ㄩ噺闂棰樸
3錛屾帶鍒跺ソ闃層佹帓姘寸郴緇熸柦宸ヨ川閲忥細瀵規帓姘寸$殑鎺ュご閮ㄤ綅瑕侀噸鐐規鏌ャ
4銆佸勭悊濂芥槑鎸栧洖濉孌電殑闃叉按銆傛帶鍒跺ソ鍥炲~鍦熺殑璐ㄩ噺銆佸帇瀹炴晥鏋滐紝淇濇姢濂介槻姘村眰錛岄噸鐐瑰仛濂芥帓姘淬
5銆佸唴琛ユ柦宸ュ墠鍔″繀鍋氬ソ鎺ョ紳絳夊勭殑娓楁紡姘哄勭悊銆
④ 闅ч亾闃叉按鏉挎柦宸ュ伐鑹轟粙緇嶏紵
鐜伴樁孌碉紝寤虹瓚浼佷笟濡備綍榪涜岄毀閬撻槻姘存澘鏂藉伐宸ヨ壓錛熶富瑕佹儏鍐靛寘鎷浠涔堝唴瀹癸紵浠ヤ笅鏄涓杈懼挩璇㈠皬緙栨⒊鐞嗛毀閬撻槻姘存澘鏂藉伐宸ヨ壓涓撲笟寤虹瓚鏈璇鐩稿叧鍐呭癸紝鍩烘湰鎯呭喌濡備笅錛
灝忕紪閫氳繃寤虹瓚琛屼笟鐧劇戠綉絝欌斺斿緩絳戠綉寤虹瓚鐭ヨ瘑涓撴爮榪涜屾煡璇錛屾⒊鐞嗛毀閬撻槻姘存澘鏂藉伐宸ヨ壓鐩稿叧璧勬枡鎯呭喌錛屽熀鏈鍐呭瑰備笅錛
闅ч亾鏂藉伐涓鐨勯槻鎺掓按鏂藉伐涓鐩存槸闅ч亾鏂藉伐涓鐨勮杽寮遍」錛屼互寰閫氬父鐨勬柦宸ユ柟娉曟瘮杈冭垂鍔詫紝緇忚繃鍦ㄦ柦宸ョ幇鍦轟笉鏂鎽哥儲錛屾垜浠瀵瑰叾榪涜屼簡涓浜涙敼榪涳紝浣挎敼榪涘悗鐨勬柦宸ユ柟娉曞彉寰楃畝鍗曟柟渚褲佹槗浜庢帉鎻★紝涓旈珮鏁堣妭綰︺
闃叉按鏉挎柦宸ュ噯澶
鍦ㄩ夎喘濂介槻姘存澘涔嬪悗錛岄摵璁鵑槻姘存澘涔嬪墠錛岄渶瑕佸歸摵璁懼湴鍩轟綔澶勭悊銆傛竻鎵閾鴻劇殑騫抽潰錛屽熀浣撳潥瀹炪佸鉤鏁淬佷笉鍑瑰嚫錛岃〃闈㈡棤瑁傜汗浠ュ強灝栭攼鐗┿侀搧涓濄佺煶鍧楃瓑鏉傜墿銆傚傛灉瑕佸硅崏鐨絳夊湴閾鴻鵑槻姘存澘錛岃佹竻闄ゆ爲鏍癸紝鍠鋒柦鐏鑽夊墏浠ラ櫎鍘繪潅鑽夈備笌鑶滄帴瑙﹂潰鏃訛紝瑕侀摵璁劇矑寰勫皬鐨勭爞鍦熸垨綺樺湡灞備綔闃叉姢灞傦紝涓旈槻鎶ゅ眰瑕嗙洊鍘氬害搴斿ぇ浜庣瓑浜30銕濄
闃叉按鏉挎柦宸ユ柟娉
閾鴻鵑槻姘存澘鏃跺皢闃叉按鏉挎部涓瀹氱殑鏂瑰悜閾猴紝鎷夌洿鍗沖彲錛屽苟鐣欐湁涓瀹氱殑浼哥緝絀洪棿銆傚湪閾鴻捐繃紼嬩腑錛岃皟鏁村ソ姣忎竴涓鍗曞厓鐨勮蛋鍚戱紝榪欐牱灝辨湁鍒╀簬姣忎釜鍗曞厓涔嬮棿鐨勭剨鎺ャ備互涓婇摵璁懼仛濂藉悗鐢ㄦ矙琚嬪帇浣忥紝騫朵負鏈鍚庣殑杈圭紭鐒婃帴浣滃噯澶囥
闃叉按鏉挎敞鎰忎簨欏
鏂藉伐鏃惰佷繚璇侀摵璁懼熀浣撶殑鏁存磥銆傛矙琚嬭佸皢闃叉按鏉垮帇騫熾佸帇紼熾傜剨鎺ュ悗瑕侀槻姝㈡帴緙濆勬棤娌規薄銆佹按鍒嗐佺矇灝樼瓑銆傜剨鎺ュ墠瑕佽皟鏁村ソ鎺ョ紳澶勪袱騫呰竟PE鍗曡啘,浣誇箣鎼鎺ヤ竴瀹氱殑瀹藉害,鎼鎺ュ藉害涓鑸涓6鍀8銕濅笖騫蟲暣,鏃犳姌鐨
鏇村氬叧浜庢爣涔︿唬鍐欏埗浣滐紝鎻愬崌涓鏍囩巼錛岀偣鍑誨簳閮ㄥ㈡湇鍏嶈垂鍜ㄨ銆
⑤ 隧道防水板施工方法是什麼
防水板採用無釘鋪設,板縫間連接利用材料本身熱合,焊接嚴密可靠。施工中使用作業台架,台架長4.5m。先進行基面處理,然後鋪設防水層,基面處理通常超前於防水層作業兩個循環。
復合型防水板厚1.5mm(300g/m2無紡布),幅寬2.5米。採用吊帶式施工方法鋪設,即利用主板與無紡布之間粘貼的布吊帶將防水板固定在暗釘上;防水板縫間連接採用熱風雙焊縫施工工藝焊接,搭接長度15cm。
防水板鋪設:利用防水板背後的布吊帶將防水板固定於暗釘上。防水板固定點間距:拱部為0.5~0.7m,側牆為1.0~1.2m,在凹凸處適當增加固定點,點間防水層不得綳緊,保證二次模注砼澆注時不損壞防水板。
隧道防水板施工注意事項
隧道防水板鋪設之前,噴混凝土表面鋼筋頭與錨桿頭先切除,再用手持砂輪機將其磨平,對凹凸不平的部位應該進行修鑿噴補,使混凝土表面平順,局部有滲水處,應該及時進行處理。
隧道防水板按環向鋪設,焊接工序和固定工序應緊密配合,一般是先焊接後固定,隧道防水板鋪設的搭接寬度為10厘米,焊接寬不小於2厘米。漏焊、假焊處應該補焊,如果有烤焦、焊穿處,應該用同樣的防水板焊貼覆蓋或按監理工程師指示辦理。
以上內容參考網路-防水板、網路-隧道施工